Basic Overcurrent Protection, Motor Protection, Generators, High Level Differential Protection
High Tech Line Protection for Low, Medium and High Voltage (LV, MV, HV) have a range of protection functions. The protection includes time overcurrent protection, mechanical protection, high quality differential protection.
In addition to simple relays, there are also multifunction devices mounted on the door or in separate cabinets. An adapter is available for mounting on the rear panel.
An intuitive display of output values and error messages is provided via an alphanumeric display and LEDs.
Connections to SCADA systems are achieved through standardized interfaces.
Manuál
ANSI | ||||||||||||||||
Zařízení | MRI3-I | MRI3-IR | MRI3-IRE | MRI3-IE | MRI3-IER | MRI3-IT | MRI3-ITE | MRIK3-I | MRIK3-IE | MRIK3-ICE | MRIK3-ICX | MRI3-ICE | MRI3-ICX | MRI1-IE | IRI1-ER | |
Dokumentace | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | ——- | |
Typová řada (Line) | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | HTL | |
Proudové transformátorové vstupy (MTP) | 3 | 3 | 4 | 4 | 4 | 3 | 4 | 3 | 4 | 4 | 4 | 4 | 4 | 4 | 1 | |
Napěťové transformátorové vstupy (MTN) | – | 3 | 3 | – | 3 | – | – | – | – | – | – | – | – | – | – | |
Binární vstupy | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 5 | 5 | 7 | 7 | 7 | 7 | 2 | – | |
Výstup relé | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 1 | |
Watchdog relay | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | – | |
50/51 | Nadproudová ochrana časová | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – |
Přechodová stabilizace | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | |
67 | Řídící nadproudová ochrana časová | – | Ano | Ano | – | – | – | – | – | – | – | – | – | – | – | – |
50N/51N | Zemní ochrana | – | – | Ano | Ano | Ano | – | Ano | – | Ano | Ano | – | Ano | – | Ano | Ano |
50SN/51SN | Citlivý EF izolovaný / Kompenzovaný | – | – | – | – | – | – | – | – | – | – | Ano | – | Ano | – | – |
50N/51N | Zemní odpor / Přímé uzemnění | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – |
67N | Zemní směrová ochrana | – | – | – | – | Ano | – | – | – | – | – | – | – | – | – | – |
49 | Tepelné zobrazení | – | – | – | – | – | Ano | Ano | – | – | – | – | – | – | – | – |
50BF | Elektrický ochraný jistič | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – |
64REF | Diferenciální ochrana : Zemní rozdílová ochrana | – | – | – | – | – | – | – | – | – | – | – | – | – | – | Ano |
79 | Opětovné zapínaní relé AR | – | – | – | – | – | – | – | Ano | Ano | Ano | Ano | – | – | – | – |
Reset / Blokace | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – | |
Napěťově závislá funkce | – | – | – | – | – | – | – | – | – | – | – | – | – | – | – | |
Časová data | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – | – | |
Parametry | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 1 | – | |
Chybová hlášení | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – | |
Záznam poruch | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – | – | |
Výstup relé matrix | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – | |
Ovládání a monitorování výkonového vypínače | – | – | – | – | – | – | – | – | – | Ano | Ano | Ano | Ano | – | – | |
RS485 Open Data Protocol | Ano | Ano | Ano | Ano | Ano | Ano | Ano | – | – | – | – | – | – | Ano | – | |
Modbus RTU protokol | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Ano | Ano | Ano | Ano | Volitelný | – | |
Profibus DP | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitlný | Volitelný | Volitelný | – |
ANSI | |||||||
Zařízení | MRN3-1 | MRN3-2 | MRN3-3 | MRU3-1 | MRU3-2 | ||
Dokumentace | Manuál | Manuál | Manuál | Manuál | Manuál | ||
Typová řada (Line) | HTL | HTL | HTL | HTL | HTL | ||
Proudové transformátorové vstupy (MTP) | – | – | – | – | – | ||
Napěťové transformátorové vstupy (MTN) | 3 | 3 | 3 | 3 | 3 | ||
Binární vstupy | 2 | 2 | 2 | 2 | 2 | ||
Výstup relé | 4 | 4 | 4 | 4 | 4 | ||
Watchdog relay | 1 | 1 | 1 | 1 | 1 | ||
50/51 | Nadproudová ochrana časová | – | – | – | – | – | |
27/59 | Napěťová ochrana | Ano | Ano | Ano | Ano | Ano | |
59N | Zbytkové napětí | – | – | – | Ano | Ano | |
47 | Fázová symetrie | – | – | – | – | Ano | |
81O/U | Kmitočtová ochrana | Ano | Ano | Ano | – | – | |
81 | Frekvenční ochrana | – | Ano | Ano | – | – | |
78 | Vektorový posun | Ano | – | Ano | – | – | |
Reset / Blokace | Ano | Ano | Ano | Ano | Ano | ||
Napěťově závislá funkce | Ano | Ano | Ano | – | – | ||
Časová data | Ano | Ano | Ano | Ano | Ano | ||
Parametry | 2 | 2 | 2 | 2 | 2 | ||
Chybová hlášení | Ano | Ano | Ano | Ano | Ano | ||
Záznam poruch | Ano | Ano | Ano | Ano | Ano | ||
Výstup relé matrix | Ano | Ano | Ano | Ano | Ano | ||
RS485 Open Data Protocol | Ano | Ano | Ano | Ano | Ano | ||
Modbus RTU Protokol | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | ||
Profibus DP | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný |
ANSI | |||||||
Zařízení | MRG3 | MRG3-I | MRG3-U0 | MRG3-IE | MRG3-IU0 | MRG3-IER | |
Dokumentace | Manuál | Manuál | Manuál | Manuál | Manuál | Manuál | |
Typová řada (Line) | HTL | HTL | HTL | HTL | HTL | HTL | |
Proudové transformatorové vstupy (MTP) | – | 3 | – | 4 | 3 | 4 | |
Napěťové transformatorové vstupy (MTN) | 3 | 3 | 4 | 3 | 4 | 4 | |
Binární vstupy | 2 | 2 | 2 | 2 | 2 | 2 | |
Výstup relé | 4 | 4 | 4 | 4 | 4 | 4 | |
Watchdog relay | 1 | 1 | 1 | 1 | 1 | 1 | |
50/51 | Nadproudová ochrana časová | – | Ano | – | Ano | Ano | Ano |
50N/51N | Zemní ochrana | – | – | – | Ano | – | Ano |
50N/51N | Zemní odpor / Přímé uzemnění | – | – | – | – | – | Ano |
67N | Zemní směrová ochrana | – | – | – | – | – | Ano |
50BF | Elektrický ochraný jistič | – | Ano | – | Ano | Ano | Ano |
27/59 | Napěťová ochrana | Ano | Ano | Ano | Ano | Ano | Ano |
59N | Zbytkové napětí | – | – | Ano | – | Ano | – |
81O/U | Kmitočtová ochrana | Ano | Ano | Ano | Ano | Ano | Ano |
81 | Frekvenční ochrana | Ano | Ano | Ano | Ano | Ano | Ano |
78 | Vektorový posun | Ano | Ano | Ano | Ano | Ano | Ano |
Reset / Blokace | Ano | Ano | Ano | Ano | Ano | Ano | |
Napěťově závislá funkce | Ano | Ano | Ano | Ano | Ano | Ano | |
Časová data | Ano | Ano | Ano | Ano | Ano | Ano | |
Parametry | 2 | 2 | 2 | 2 | 2 | 2 | |
Chybová hlášení | Ano | Ano | Ano | Ano | Ano | Ano | |
Záznam poruch | Ano | Ano | Ano | Ano | Ano | Ano | |
Výstup relé matrix | Ano | Ano | Ano | Ano | Ano | Ano | |
RS485 Open Data Protocol | Ano | Ano | Ano | Ano | Ano | Ano | |
Modbus RTU Protokol | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | |
Profibus DP | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný | Volitelný |
ANSI | ||||||||
1 | Zařízení | MRP2-3IU | MRP2-R3IU | MRR1 | MRQ1 | |||
Dokumentace | Manuál | Manuál | Manuál | Manuál | ||||
Typová řada (Line) | HTL | HTL | HTL | HTL | ||||
Proudové transformátorové vstupy (MTP) | 3 | 3 | – | 1 | ||||
Napěťové transformátorové vstupy (MTN) | 3 | 3 | – | 3 | ||||
Binární vstupy | 2 | 2 | 2 | 2 | ||||
Výstup relé | 4 | 4 | 4 | 4 | ||||
Watchdog relay | 1 | 1 | 1 | 1 | ||||
50BF | Elektrický ochraný jistič | Ano | Ano | – | – | |||
32/37 | Směrový výkon | Ano | Ano | – | – | |||
64N | Rotorová zemní ochrana | – | – | Ano | – | |||
40/76 | Budící proudová ochrana | – | – | Ano | – | |||
Porucha diody | – | – | Ano | – | ||||
46 | Negativní sekvenční ochrana | – | – | – | – | |||
40 | Provozní chybějící ochrana | – | – | – | Ano | |||
Reset / Blokace | Ano | Ano | Ano | Ano | ||||
Napěťově závislá funkce | Ano | Ano | – | – | ||||
Parametry | 1 | 1 | 1 | 1 | ||||
Chybová hlášení | Ano | Ano | – | – | ||||
Výstup relé matrix | Ano | Ano | Ano | – | ||||
RS485 Open Data Protocol | Ano | Ano | Ano | Ano | ||||
Modbus RTU Protokol | Volitelný | Volitelný | – | – |
ANSI | |||
Zařízení | MRM3-2I | MRM3-2IE | |
Dokumentace | Manuál | Manuál | |
Typová řada (Line) | HTL | HTL | |
Proudové transformátorové vstupy (MTP) | 3 | 4 | |
Binární vstupy | 7 | 7 | |
Výstup relé | 4 | 4 | |
Watchdog relay | 1 | 1 | |
50/51 | Nadproudová ochrana časová | Ano | Ano |
50N/51N | Zemní ochrana | – | Ano |
49 | Tepelné zobrazení | Ano | Ano |
50BF | Elektrický ochraný jistič | Ano | Ano |
46 | Negativní sekvenční ochrana | Ano | Ano |
51 | Motorová ochrana : Blokovaný rotor | Ano | Ano |
48 | Motorová ochrana : Nedokončený start | Ano | Ano |
66 | Motorová ochrana : Max. číslo pro start | Ano | Ano |
37 | Motorová ochrana : Podproudová | Ano | Ano |
49 | Motorová ochrana : Tepelná ochrana | Ano | Ano |
Reset / Blokace | Ano | Ano | |
Časová data | Ano | Ano | |
Parametry | 2 | 2 | |
Chybová hlašení | Ano | Ano | |
Záznam poruch | Ano | Ano | |
Výstup relé matrix | Ano | Ano | |
RS485 Open Data Protocol | Ano | Ano | |
Modbus RTU Protokol | Volitelný | Volitelný | |
Profibus DP | Volitelný | – |
ANSI | |||||
Zařízení | MRA1 | MRL1 | MRT1 | ||
Dokumentace | Manuál | Manuál | Manuál | ||
Typová řada (Line) | HTL | HTL | HTL | ||
Binární vstupy | 1 | 4 | – | ||
Výstup relé | 2 | 4 | – | ||
Watchdog relay | – | – | – | ||
50BF | Nadproudová ochrana časová | – | – | – | |
Opětovné zapínání relé | – | – | – | ||
Reset / Blokace | – | – | – | ||
Parametry | – | – | – | ||
74TC | Kontrola regulačního obvodu | Ano | – | – | |
86 | Pomocné relé | – | Ano | – | |
Test block | – | – | Ano | ||
Capacitor storage | – | – | – | ||
RS485 Open Data Protocol | – | – | – |